ILX LIGHTWAVE OMH-6742B CALIBRATION and ILX LIGHTWAVE OMH-6742B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ILX LIGHTWAVE OMH-6742B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Power Sensor?
Shop for Comparable Products on our
 used Optical Power Sensor page or new Optical Power Sensor page

 
   ILX LIGHTWAVE OMH-6742B   Description / Specification:    
ILX LIGHTWAVE OMH-6742B 350 to 1100 nm Silicon Optical Power/Wavelength Head

The ILX OMH-6742B Silicon Power/WaveHead, when coupled to an OMM-6810B Optical Meter, provides the capability to accurately measure the power and wavelength of laser sources between 350 and 1100 nm. Easy mounting, quick setup and alignment, and a two meter cable make the ILX Lightwave Optical
Measurement Head easy to integrate into an experiment.
Specifications.


Power Measurement.
Range: 100 nW ~ 1 W; -40 dBm ~ +30 dBm.
Accuracy: ±3.5% (440 to 1000 nm).

Wavelength Measurement.
Range: 350 to 1100 nm.
Accuracy: ±1.0 nm.
Temperature Coefficient: <±0.03 nm / °C.
Linearity with Power Change: <±0.5 nm.

Sampling Rate:
  Slow 16 samples @ 60 ms / sample,
  Medium 4 samples @ 60 ms / sample,
  Fast 1 sample @ 60 ms / sample.
Input Bandwidth:
  Slow 1 Hz,
  Medium 10 Hz,
  Fast 60 Hz.



 



Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Length
Average distance over which superimposed waves lose their phase relationships

Linewidth
Linewidth is the width of a spectral line in terms of wavelength, wave number and frequency.

Power Flatness Versus Wavelength
When changing the wavelength at constant power setting and recording the differences between actual and displayed power levels, the power flatness is ± half the span (in dB) between the maximum and the minimum of the measured power levels.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).

Telecom Bands
Optical fiber communications typically operate in a wavelength region corresponding to one of the following Bands. O Band (original): 1260–1360 nm. E Band (extended): 1360–1460 nm. S Band (short wavelengths): 1460–1530 nm. C Band (conventional): 1530–1565 nm. L Band (long wavelengths): 1565–1625 nm. U Band (ultralong wavelengths): 1625–1675 nm


Please contact us for your ILX LIGHTWAVE OMH-6742B CALIBRATION and/or ILX LIGHTWAVE OMH-6742B 350 to 1100 nm Silicon Optical Power/Wavelength Head REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: